shing 寫到: | tried from bib apartment.
3. you can buy any other type that equal the size of eric's design, you can buy the special screw from there http://www.swagelok.com. price around hk$60 ~ 90.
|
Eric mentioned that the thermocouple adaptor is custom made by Swagelok.
Did you request Swagelok to quote for Eric's design. Please reserve one for me if you are ordering from Swagelok.
Thanks,
SimonCHAN |
|
回頂端 |
|
|
shing Site Admin
註冊時間: 2006-03-01 文章: 1100
|
發表於: 星期四 七月 10, 2008 4:21 pm 文章主題: |
|
|
i am no rich, hk$10.00 is more suitable for me.
order by yourself, p/n ss-200-1-0221bt.
you can buy any kind of digital probe thermometer in ssp, after buying the thermometer, measure the probe size, such as 5/32", then go to reclamation street, buy in tube size 5/32" in. , outter connect m6 x 6 or 7mm. must must remember, if measure 1/8", must must buy 1/8" in. in tube. many brands on the reclamation street, no only swaglok ar. _________________ http://www.hkcoffee.com
http://twitter.com/hkcoffee
seize the day |
|
回頂端 |
|
|
lit.rice
註冊時間: 2007-12-22 文章: 637
|
|
回頂端 |
|
|
Designer
註冊時間: 2006-09-09 文章: 205 來自: HK
|
發表於: 星期四 七月 10, 2008 6:46 pm 文章主題: |
|
|
??????????????????????HX??Cooling flush timing & volumn?????????brewing temperature????
??????????boiler pressure???????Cooling flush timing??? |
|
回頂端 |
|
|
pillowpaky
註冊時間: 2007-11-24 文章: 696
|
發表於: 星期五 七月 11, 2008 4:02 pm 文章主題: |
|
|
???????HX???E61?espresso machine???
?????????????? "????" ??????HX??????
??????????? ???????????????
????PID???????HX????????
Simon??
??????????????????...?3??update????
????expobar??????2?PID???(?????2????????1?PID??)
?????????????????????????????
??????PID??????????????????(0.5?)
?????????????????????????????
??????PID??????????????GS3?????(???????)
??????????????????????PID
??0.1F???PID??APID???????????????(??????)
????????????????????
http://www.youtube.com/watch?v=PivmkXWivP8 _________________
http://pillowpaky.blogspot.com/
pillowpaky 在 星期六 七月 12, 2008 11:54 am 作了第 1 次修改 |
|
回頂端 |
|
|
Designer
註冊時間: 2006-09-09 文章: 205 來自: HK
|
發表於: 星期五 七月 11, 2008 7:39 pm 文章主題: |
|
|
Rotary pump + double boiler + PID???? |
|
回頂端 |
|
|
SimonCHAN
註冊時間: 2008-05-31 文章: 270 來自: HKSAR
|
發表於: 星期六 七月 12, 2008 1:03 am 文章主題: |
|
|
Dear Pillowpaky,
Is the machine in the video yours.
It seems water was running out from the screw hole of the E61 grouphead.
By this method, only static (no loading) temperature can be measured.
When the machine is loaded (with coffee), water would run out much slower (i.e. water stay longer in the heat exchanger to be heated up ) and the brewing temperature (when water meet the coffee) would be higher.
Eric's adaptor make measuring of dynamic temperature possible. As the thermocouple is positioned close to the coffee, the measured temperature is closed to the actual brewing temperature.
There is cheaper method to measure the brewing temperature but less convenient.
Somebody just tie a thermo bead to the screw of the shower screen.
Just my 2 cents.
SimonCHAN |
|
回頂端 |
|
|
pillowpaky
註冊時間: 2007-11-24 文章: 696
|
發表於: 星期六 七月 12, 2008 2:33 am 文章主題: |
|
|
Designer 寫到: | Rotary pump + double boiler + PID???? |
???????????????????????
???????????????0.5?????????
?????????????????????
???????????
?????????????????????????
???????????????90???
????????????????88-92????
????????90????????????????
??????????????????1.5???
??????????????1.2?1.8????????
??????1.5?????????????????????
??????Krups?expobar??????????
Krups4020???????(??????shot?keep???)
?expobar???????
????Krups????shot?????????2?shot?????????
?expobar??????????? _________________
http://pillowpaky.blogspot.com/ |
|
回頂端 |
|
|
pillowpaky
註冊時間: 2007-11-24 文章: 696
|
發表於: 星期六 七月 12, 2008 2:47 am 文章主題: |
|
|
SimonCHAN 寫到: |
Dear Pillowpaky,
Is the machine in the video yours.
It seems water was running out from the screw hole of the E61 grouphead.
By this method, only static (no loading) temperature can be measured.
When the machine is loaded (with coffee), water would run out much slower (i.e. water stay longer in the heat exchanger to be heated up ) and the brewing temperature (when water meet the coffee) would be higher.
Eric's adaptor make measuring of dynamic temperature possible. As the thermocouple is positioned close to the coffee, the measured temperature is closed to the actual brewing temperature.
There is cheaper method to measure the brewing temperature but less convenient.
Somebody just tie a thermo bead to the screw of the shower screen.
Just my 2 cents.
SimonCHAN |
Simon?
video????????????"??"??(????)?
?????????"??"?????
???????????HX?????????????????????
??????????????????
?????????????????????"????"?
??????"??"?"???"
????shing???????????????
simon?????????????????????? _________________
http://pillowpaky.blogspot.com/ |
|
回頂端 |
|
|
SimonCHAN
註冊時間: 2008-05-31 文章: 270 來自: HKSAR
|
發表於: 星期六 七月 12, 2008 12:30 pm 文章主題: |
|
|
pillowpaky 寫到: |
?????????????????????"????"?
??????"??"?"???" |
?????
pillowpaky 寫到: |
????shing???????????????
simon?????????????????????? |
???????????????PID???煱????温?
SimonCHAN |
|
回頂端 |
|
|
pillowpaky
註冊時間: 2007-11-24 文章: 696
|
發表於: 星期六 七月 12, 2008 4:53 pm 文章主題: |
|
|
SimonCHAN 寫到: |
???????????????PID??????????
SimonCHAN |
???????????PID??????
?"??"Video????PID????????????0.1????
?????????PID??????????
?????????????????????????????
???????????????????????????
SimonCHAN 寫到: |
?????????"????"?
??????"??"?"???"
?????
SimonCHAN |
??HX?Dual Boiler
?????? ???????????????
?????????????????????2??
??????????????????????????????
???1shot????93?????????????????????????
????
??????????????????????
???
????????????????Tamp????????????
???????????????????????
????????
????????110???????
??110??????
?105?????????????113???????????
????110??????
??????????????????
???????93?.......????
????"?????"??????
????????????????????...??..
???simon?????
When the machine is loaded (with coffee), water would run out much slower (i.e. water stay longer in the heat exchanger to be heated up ) and the brewing temperature (when water meet the coffee) would be higher.
?????...
HX???????????????(??)????????
???????????
???????????????
????????????????Tamp????????????????
?HX?????????????????
????=???????????????
??????HX???PID
???????90????????????
??????????????90
?????????????"??"
??HX???PID?????????
??????????????(?????)????????
????????????????????????
??????????????????????
????????????
?????????.........?shot???? _________________
http://pillowpaky.blogspot.com/ |
|
回頂端 |
|
|
Designer
註冊時間: 2006-09-09 文章: 205 來自: HK
|
發表於: 星期六 七月 12, 2008 6:24 pm 文章主題: |
|
|
Hi! pillowpaky,
?????HX?? brewing ??boiler refill water o????????????????espresso?steam milk?????????espresso o????tank?thermosyphon?brew head?HX?refill??o?cycling time??????????water dispenser????? |
|
回頂端 |
|
|
shing Site Admin
註冊時間: 2006-03-01 文章: 1100
|
發表於: 星期日 七月 13, 2008 6:45 am 文章主題: |
|
|
??pillowpaky ?point ??hx ?d ??, ???e61 brewing ???cooling flush, cooling flush ??????, ??cooling flush ?6sec, brewing temperature 200 degree f, ??????cooling flush ?6sec, brewing temperature ??200 degree f, ??200, ????keep 2x ?. ??????strem boiler pressure ??, ?????strem boiler ?????. la spaziale ??????, ???????, ????. _________________ http://www.hkcoffee.com
http://twitter.com/hkcoffee
seize the day |
|
回頂端 |
|
|
Designer
註冊時間: 2006-09-09 文章: 205 來自: HK
|
發表於: 星期日 七月 13, 2008 9:06 am 文章主題: |
|
|
Hi Shing,
?????HX???check???idle time?(??3mins, 5mins & after 10 mins)o??????????????brewing ?2x?????????????3,4?tamp?o?portafilter???shots?Cooling flush????????o??????Flush & Go? Flush & Wait (for rebounce time) method????????????idle time???????water dancing sound?????????????o??????????????Erics Thermocouple Device ????????
????????boiler?D?Shing?modify??Expobar o?brew boiler PID?????fit??
Btw,??12?ProAc??? re run-in??
http://freshcoffeentea.no-ip.info/phpbb2/viewtopic.php?t=1794 |
|